D16XLCD NESS Alarm Panel / Dialler With LCD Keypad Ness 56 User Codes Can Be Assigned To 3 To 6

D16XLCD NESS Alarm Panel / Dialler With LCD Keypad Ness 56 User Codes Can Be Assigned To 3 To 6

 
NESS D8x & D16x PANELS

Flexible 8 Zone control panel & Dialler. The Ness D8x is the most versatile Ness 8 zone control panel ever! The D8x is available in Led keypad or LCD keypad models to suit any preference.Supplied with keypad, plug pack, battery, telephone lead, housing and manuals.

Panel & Siren Kits include the control panel complete with keypad, plugpack, battery, plus external horn speaker, siren cover, strobe light and PIR detectors from the Ness Quantum range. Easy and convenient to order control panel and siren kits.

56 user codes

  • Each user code can be assigned to Area1, Area2, CodeOnly Arming, Arm Only, Keypad Code, Radio Code, Access Code Reader1, 2 or 3.

Access Control Functions

  • New access control features with flexible programming options. Connect up to 3 access control proximity Weigand readers. Use the access control option to open electric door locks or arm/disarm the panel or both!

Arm/Disarm using prox cards

  • The access control feature allows up to 55 individual users to arm and disarm using proximity access cards. Prox cards can even be used tooperate electric doors locks for secure hands free entry.

Modular Housing

  • The new EB04 enhanced housing is tough and roomy with a removable lid for easy access. The housing is generously fitted with multiple standoff positions, cable tie loops, cable/conduit entry points and uniqueslide-in carriers for the new X Series accessory boards.

AccessorIes

  • A new range of X Series slide-in accessory boards includes a four Relay Board, a Reader Interface and the new X Series Output Expander for both the D8x and D16x panels.

D16x C-Bus Panel

    FEATURES:
    Main Software FEATURES
    • 56 user codes can be assigned to 3 to 6 digits PIN codes with keypad options including Area assignment, Arm Only options, Code Onlyarming and
      much more.
    • Two button arming feature.
    • Fire Alarm feature with different siren tones.
    • Input to output mapping.
    • Programmable 2 area partitioning with overlapping of zones allowed.
    • Programmable sensitivity for vibration sensors - zone by zone basis.
    • Programmable Long Response times for zones (1sec or3sec).
    • Monitor mode and Day Zone feature.
    • Temporary Day Zone feature for Day Zone setup "On the fly".
    • Single or double trigger option on a zone-by-zone basis.
    • Supports up to 55 Radio Keys.
    • Access Control feature with provision for up to 3 Readers
    • Supports up to 55 Proximity Access Cards or Fobs.
    • Uses NessComms up/download software package
    • Secure DTMF remote arming/disarming capabilities.
    • Programmable siren/reset lockout.
    • 30 event memory from keypad
    • Expanded event memory can be accessed by NessComms™.
    • Disable unused zones feature.
    • Siren chirp/strobe flash on radio key arming with ‘quiet chirp' option.
    • Standard defaults to suit most applications.
    • Quiet chirps on Arm / Disarm option.

    and much more...

    Main Hardware FEATURES

    • 8 or 16 fully programmable zones.
    • D16x has 16 physical zone inputs or Zone Split option.
    • 2 additional 24hr inputs.
    • End Of Line supervision 2K2 or 3K3 programmable.
    • D8x supports up to 3 remote LED or LCD Keypads.
    • D16x supports up to 3 remote LCD Keypads.
    • Plug-in Radio Interface supports any Ness radio device
    • Direct connect upload/download via the Serial port.
    • 2-way serial data comms via the Serial port - interface with external devices.
    • Reader port connects up to 3 addressable access control readers.
    • Output Expander option for both D8x and D16x.
    • New Listen pins allow the installer to diagnose dialler tones on site.
    • True dynamic battery test hourly.
    • 4 programmable auxiliary outputs.
    • Programmable REX inputs for access control.
    • Automatic resetting fuses on all outputs.
    • Optional latching or momentary keyswitch arming option.
    • Option for an extension sonalert to mimic all keypad beeps.
    • New attractive and versatile housing with installerfriendly design.
    • Plug in accessory boards available.
    • Complies with all relevant Australian and CE standards.

    and much more...

    DIALER

    • Full remote upload/download by PC and modem using NessComms™ software.
    • Remote control of outputs via telephone.
    • Contact ID Format or audible voice format. (Except D16x C-Bus version).
    • Two 30 digit phone numbers plus a temporary "follow me" number.
    • Phone line monitoring (activates output).
    • Dialler ‘Listen in' option for installers.
    • Auto Test calls at programmable intervals.
    • Pulse or DTMF dialling.
    • True dial tone detection.
    SPECIFICATIONS:
    • Box dimensions: 235w x 300h x 90d mm.
    • Plug pack: 240V AC, output 17V AC@1.4A.
    • Power supply: 13.8V DC @ 800mA.
    • Quiescent current draw: 80mA with 1 keypad.
    • Operating voltage: 9.5V- 14V DC.
    • Rechargeable battery: 12 volt 7.0 Amp/hour Sealed Lead Acid.
    • Battery charging current: 350mA maximum, current limited.
    • Dynamic battery test: Backup battery is tested under load, hourly and on arming.
    • Fuses: 2 Amp auto resetting / Siren output & Reset output.
      • 500mA auto resetting / 12 volt auxiliary outputs.
      • 200 mA auto resetting / strobe output.
    • Zone inputs: 8 or 16 zone inputs. 2 x 24hr tamper inputs.
    • End of line resistor:
      • 2200 Ohms (2K2) or 3K3 programmable.
      • D16 Zone Split option uses 3K3+4K7.
    • Maximum keypads: 3.
    • RADIO Header: Multi-pin connector for the Ness Radio Interface.
    • SERIAL Header: Serial data port for direct connect programming using NessComms™ software. Also 2 way serial data (V5.6+)
    • READER Header: Multi-pin port for connecting up to 3 Ness proximity access card readers.
    • Siren output: On board siren driver with timed output. Maximum 3 x 8 Ohm horn speakers.
    • Strobe output: 12V DC timed output. Maximum 2 x 1 Watt strobe lights.
    • Reset output: 12V DC timed output. Max. 3 x 12V piezo screamers.
    • Equipment power output: 13.8V DC output for powering detectors and other equipment. Maximum 500mA.
    • AUX Header: Multi-pin connector provides outputs Aux1, Aux2, Aux3, Aux4, 12V DC.

Weight: 4.8170

Aussie Stock
All our stock is kept in our Melbourne based warehouse. Our stock levels are also updated every 10 minutes! So if it says 10 units in stock, you can trust that it is accurate.

No PO Boxes or Parcel Lockers
At this stage we only use couriers and can only deliver to a road-side address. This means PO Boxes and Parcel Lockers cannot be accepted as StarTrack do not deliver to these addresses.
In instances where a PO Box or Parcel Locker address in entered, we may ask for an alternative road-side address, or cancel and refund your order immediately and urge you to replace your order with an alternative delivery address.

Delivery times
We typically dispatch our goods same day or next day. From there, you can expect 2 - 8 business days Australia wide. Most capital cities can expect 1-2 day delivery times.
Any RTS (Return to Sender) orders due to missing or incorrect address information entered by the buyer may incur an additional charge for redelivery.
MPN: D16XLCD

Shipping Details

  • Estimated Delivery Time:
    • Metro Areas: 1-2 business days
    • Rural and Remote Areas: 2-8 business days
  • Delivery Note:
    • No delivery to PO Box addresses or Parcel Lockers (please provide residential or business address at checkout)
    • Any RTS (Return to Sender) orders due to missing or incorrect address information entered by the buyer may incur an additional charge for re-delivery
    • Please note that orders are shipped using a courier service and require a signature. If you do not require a signature for your order or the item can be left safely, please add a note to the order advising of "Authority to leave"

RETURNS POLICY

To return goods we have delivered to you, please contact us within 30 days from the date you have received the item. A staff member will then assist you with any return or repair. This may include inspecting the goods, arranging for the goods to be sent for repair, or providing you with a replacement.

Incorrectly Ordered/Change Of Mind:

Refunds are not normally provided where you have simply changed your mind or found the goods cheaper elsewhere. However, if goods have been incorrectly ordered, at our discretion, customers may be credited less a restocking fee.

A change of mind return will only be accepted if:

  • The item is in a brand new, sealed and resaleable condition
  • We are contacted within 30 days of the item being received
  • The item is returned to us in a timely manner

Please note: For change of mind returns, the shipping cost and method is the customer's responsibility. We will not compensate any returns that are lost or damaged in transit to us. For some change of mind returns, a restocking fee may apply.

Faulty Items

We recommend you immediately inspect any goods that we deliver to you or that you collect from our store to ensure you are completely satisfied with the goods. If any goods arrive damaged, please contact us as soon as possible. We will arrange to have the damaged goods returned and either arrange for a replacement of the goods or refund. Replacements and refunds of new products that are damaged on delivery or faulty from new requires a proof of purchase of the product and be returned with all original packaging, accessories and/or manuals included. Refunds will be made via the method of payment you used to make your purchase. If we consider the goods to have breached a consumer guarantee, any shipping costs to return the goods to us will be at our cost and compensated.

Repairs

The product must be returned with proof of purchase, it must not be modified or mistreated in any way and it must not have been serviced elsewhere. Goods returned for repair will be assessed and/or repaired within a reasonable time. You may be required to pay labour, assessment and/or freight fees, such as where goods are assessed to have been damaged by misuse or accident. We may provide you with an approximate fee; this may vary due to reasons beyond our control. In some circumstances, goods presented for repair may be replaced by refurbished goods of the same type rather than being repaired. Refurbished parts may be used to repair the goods.

Refund Guarantee Icon
Shop with peace of mind
All marketplace products are covered by our MyDeal Refund Guarantee Learn More
Sold & shipped by Radio Parts
cashback icon
platinum Seller
A seller's rating is an overall score calculated from performance metrics. Learn More
96.71%

More from this brand

Reference ID: 697572

Reviews (0) Add Review

No reviews yet