PsychometricsIndoor Design Conditions Energy Management Control Systems (EMCS) BasicsLoad CalculationsAir Conditioning Cycles Air FlowAir System ComponentsFans, Filters, Coils, and HumidifierAir System EquipmentAir-Handling Unit Packaged UnitsAir Duct Design Space Air DiffusionSound ControlBasics Operating Modes Outdoor VentilationAir and Smoke ControlAir Volume (VAV) SystemsWater and Heating SystemsRefrigerant CyclesRefrigeration System ComponentsReciprocating, Scroll, Rotary, and Screw Refrigeration SystemsHeat Pump SystemsCogenerationCentrifugal Refrigeration SystemsAir Conditioning SystemsEnergy Use IndexCost EstimationClassificationCharacteristicsSystem SelectionCommissioning Maintenance
Shan K. Wang (Alhambra, CA) holds master degrees from Harvard and MIT. He is the former Deputy Director, Chief Engineer for the Institute of Air Conditioning in Beijing, China, and has 50 years experience as a practicing engineer. He is the author of 11 books in the HVAC area.
Preface to Second Edition. Preface to First Edition. Chapter 1: Introduction. Chapter 2: Psychrometrics. Chapter 3: Heat and Moisture Transfer through Building Envelope. Chapter 4: Indoor and Outdoor Design Conditions. Chapter 5: Energy Management and Control Systems. Chapter 6: Load Calculations. Chapter 7: Water Systems. Chapter 8: Heating Systems, Furnaces, and Boilers. Chapter 9: Refrigerants, Refrigeration Cycles, and Refrigeration. Chapter 10: Refrigerants Systems: Components. Chapter 11: Refrigeration Systems: Reciprocating, Rotary, Scroll, and Screw. Chapter 12: Heat Pumps, Heat Recovery, Gas Cooling, and Cogeneration Systems. Chapter 13: Refrigeration Systems: Centrifugal. Chapter 14: Refrigeration Systems: Absorption. Chapter 15: Air Systems: Components - Fans, Coils, Filters, and Humidifiers. Chapter 16: Air Systems: Equipment - Air-Handling Units and Packaged. Chapter 17: Air Systems: Air Duct Design. Chapter 18: Air Systems: Space Air Diffusion. Chapter 19: Sound Control. Chapter 20: Air Systems: Basics and Constant-Volume Systems. Chapter 21: Air Systems: Variable-Air-Volume Systems. Chapter 22: Air Systems: VAV Systems - Fan Combination, System Pressure, and Smoke Control. Chapter 23: Air Systems: Minimum Ventilation and VAV System Controls. Chapter 24: Improving Indoor Air Quality. Chapter 25: Energy Management and Global Warming. Chapter 26: Air Conditioning Systems: System Classification, Selection, and Individual Systems. Chapter 27: Air Conditioning Systems: Evaporate Cooling Systems and Evaporative Coolers. Chapter 28: Air Conditioning Systems: Space Conditioning Systems. Chapter 29: Air Conditioning Systems: Packaged Systems and Desiccant-Based Systems. Chapter 30: Air Conditioning Systems: Central Systems and Clean-Room Systems. Chapter 31: Air Conditioning Systems: Thermal Storage Systems. Chapter 32: Commissioning and Maintenance. Appendix A: Nomenclature and Abbreviations. Appendix B: Pyschrometric Chart, Tables, and I-P Units to SI Units Conversion.
Publisher: McGraw-Hill Education - Europe
Published: United States, 1 November 2000
Format: Hardcover, 1424 pages
Other Information: 482 illustrations
Dimensions: 24.1 x 19.9 x 7.8 centimeters (2.27 kg)
Writer: S.K. Wang, etc.
Most items can be returned within 30 days of the item being shipped, provided it is in new, resalable condition.
Items can be returned after the 30 day period in compliance with the relevant consumer legislation if the item is faulty or damaged.
Fishpond Retail Limited are unable to accept Perfumes, cosmetics CDs, DVDs, games or software as returns, unless the goods are faulty or factory sealed and unopened.
If an order is damaged in transit, Fishpond Retail Limited will be happy to replace your items at no cost.
For damaged items shipped to you in the last 30 days please contact us via My Deal Help Centre.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable quality and the failure does not amount to a major failure