Due to rising electricity costs, Energy Saving has becomeone of today's most important issues. It is a trend to operate ECO - Economical mode on big capacity on-line double conversion UPS. This seems to virtually turn UPS backto Stand by (0ff-line) era.
Upsonics new ES pure sine wave line-interactive UPS are based on Energy Saving technology. In addition to providing high quality Sine Wave power and low Harmonic Distortion to support both Linear and Non-linear loads theES series has a built in wide range AVR (automatic voltage regulator) on Bypass circuit which stabilises power and makes the ES series operate even more effectively and safely than an On-line double conversion UPS operated under ECO mode.
ES pure sine wave line-interactive UPS vs On-line double conversion UPS operated under ECO mode
Line Interactive Sine wave output | 1RU UPS | Tower UPS | Rack / Tower Option for UPS | Long Run Time UPS require accompanying Battery Pack | Batt Pack | ||||||||||||
Model Energy Saver Series (ES xxx) | ES 1RU10 | ES 1RU15 | EST 10 | EST 15 | EST 20 | ESRT 10 | ESRT 15 | ESRT 20 | ESRT 30 | ESRT 50 | ESLR 10 | ESLR 15 | ESLR 20 | ESLR 30 | ESLR 50 | ESLR 75 | ES BP 3 RU |
Capacity VA/Watt | 1.0/625 | 1.5/938 | 1.0/625 | 1.5/938 | 2.0/1250 | 1.0/625 | 1.5/938 | 2.0/1250 | 3.0/1875 | 5.0/3125 | 1.0/625 | 1.5/938 | 2.0/1250 | 3.0/1875 | 5.0/3125 | 7.5/4688 | |
Input Nominal Voltage | 230 VAC | ||||||||||||||||
Voltage Range | 170 VAC ~ 300 VAC | ||||||||||||||||
Frequency | 45Hz - 70 Hz auto sensing | ||||||||||||||||
Boost Transfer | 208 VAC 2% | ||||||||||||||||
Boost Return | 218 VAC 2% | ||||||||||||||||
Buck Transfer | 252 VAC ± 2% | ||||||||||||||||
Buck Return | 242 VAC ± 2% | ||||||||||||||||
Low Voltage Transfer to Batt | 190 VAC ± 2% | ||||||||||||||||
Low Voltage Return | 200 VAC ± 2% | ||||||||||||||||
High Voltage Transfer to Batt | 286 VAC ± 2% | ||||||||||||||||
High Voltage Return | 276 VAC ± 2% | ||||||||||||||||
Output Wave Form | Pure Sine Wave | ||||||||||||||||
Efficiency | >80% | ||||||||||||||||
Overload Protection | Line Mode | >110% then buzzer alarm and amber LED continuously blinking | |||||||||||||||
Battery Mode | 110% ~ 150% for 30 seconds: >150% for 200ms, then UPS Shuts Down | ||||||||||||||||
Short Circuit Protection | Line Mode | Circuit Breaker | |||||||||||||||
Battery Mode | Electronic Circuit | ||||||||||||||||
Cold Start DC Start | Yes | ||||||||||||||||
Transfer Time | Typical <4ms | ||||||||||||||||
Battery Voltages | 24VDC | 24VDC | 24VDC | 36VDC | 36VDC | 24VDC | 36VDC | 36VDC | 36VDC | 48VDC | 24VDC | 36VDC | 48VDC | Various | |||
Battery Amp | 6V 9Ah | 6V 9Ah | 7.2Ah | 7.2Ah | 9Ah | 7.2Ah | 7.2Ah | 9Ah | 7.2Ah | 9AH | Requires ES BP 3 RU Batt Box 7.2 OR 9 Ah as required | 16 x 7.2Ah or 9Ah | |||||
LCD Display | UPS status; I/P & O/P Voltage, frequency; Load Level; Battery voltage & Level; internal temperaure Normal Green, Warning AmberFault RED | ||||||||||||||||
Audible alarm | Battery Mode | Beeping every 4 seconds | |||||||||||||||
Low Battery | Beeping every 1 second | ||||||||||||||||
UPS Fault | Continuous Beep | ||||||||||||||||
Overload | Beeping 2 x every second | ||||||||||||||||
Communications Interface | Various combinations of RS232; SNMP;USB; Dry Contact & AS 400 available as options | ||||||||||||||||
Dimensions (W/H/D in mm) | 440/44/515 | 440/44/515 | 145/210/380 | 145/210/445 | 145/210/445 | 440/88/465 | 440/132/465 | 440/132/620 | 440/88/465 | 440/132/465 | 440/132/465 | ||||||
Net Weight Kg | 18 | 20 | 16.5 | 17.5 | 22.5 | 16 | 17.5 | 24.5 | 36.9 | 49.8 | 16 | 17.5 | 24.5 | 25 | 34.6 | ||
Environment | Operating Environment | 0 - 40 Deg C Relative Humidity 0 - 95% Non Condensing | |||||||||||||||
Noise Level | Less than 55dBA (@1.0 Meter) | ||||||||||||||||
Outlets / Connections | 4IEC | 4IEC | 3IEC | 6IEC | 10IEC | 10IEC + TB | 6IEC | 10IEC | 5IEC+Terminal Block |
RETURNS POLICY
To return goods we have delivered to you, please contact us within 30 days from the date you have received the item. A staff member will then assist you with any return or repair. This may include inspecting the goods, arranging for the goods to be sent for repair, or providing you with a replacement.
Incorrectly Ordered/Change Of Mind:
Refunds are not normally provided where you have simply changed your mind or found the goods cheaper elsewhere. However, if goods have been incorrectly ordered, at our discretion, customers may be credited less a restocking fee.
A change of mind return will only be accepted if:
Please note: For change of mind returns, the shipping cost and method is the customer's responsibility. We will not compensate any returns that are lost or damaged in transit to us. For some change of mind returns, a restocking fee may apply.
Faulty Items
We recommend you immediately inspect any goods that we deliver to you or that you collect from our store to ensure you are completely satisfied with the goods. If any goods arrive damaged, please contact us as soon as possible. We will arrange to have the damaged goods returned and either arrange for a replacement of the goods or refund. Replacements and refunds of new products that are damaged on delivery or faulty from new requires a proof of purchase of the product and be returned with all original packaging, accessories and/or manuals included. Refunds will be made via the method of payment you used to make your purchase. If we consider the goods to have breached a consumer guarantee, any shipping costs to return the goods to us will be at our cost and compensated.
Repairs
The product must be returned with proof of purchase, it must not be modified or mistreated in any way and it must not have been serviced elsewhere. Goods returned for repair will be assessed and/or repaired within a reasonable time. You may be required to pay labour, assessment and/or freight fees, such as where goods are assessed to have been damaged by misuse or accident. We may provide you with an approximate fee; this may vary due to reasons beyond our control. In some circumstances, goods presented for repair may be replaced by refurbished goods of the same type rather than being repaired. Refurbished parts may be used to repair the goods.